FDR D-EVO GL
The world's first single exposure long length DR detector
This long-view single exposure detector ensures consistent,
easy patient positioning and repeatable image acquisition, reducing exam discomfort for a better
patient experience.
FDR D-EVO GL is 17x49 inches, expanding the traditional 14 inch CR
long length field of view by 3 full inches to better accommodate a variety of patient sizes and
help prevent retakes due to anatomy cut off.
Compared to multi-exposure DR, FDR D-EVO GL
enhances the workflow of long-view radiography by capturing the entire image in a single
exposure in just a few seconds, reducing the chance for patient motion-induced artifacts and
time for the patient to remain still.
Low DR dose and simplified image acquisition compared to CR
Single exposure capture and reduced acquisition time compared to multi-exposure DR
Increased patient safety and comfort through faster exam completion and lower dose
Virtual Grid™, Dynamic Visualization™ and ISS Technology
Intelligent image processing that replaces the use of a grid
Virtual Grid™ intelligent image
processing replaces the use of a grid to enhance contrast and improve clarity while reducing dose as
much as 50% compared to exams performed with a grid. Allows lower dose without sacrificing image quality
while helping prevent retakes associtaed with grid misalignment.
- Intuitively recognizes scatter effect in the image
- Precisely tunes contrast and noise control
- Eliminates misalignment factors
- Customizable grid characteristics, grid line ratio, density and interspacing material
- Can be applied to all body parts,* including chest, abdomen, head, spine, pelvis, upper and
lower extremities.
Refined Dynamic Visualization image processing produces exceptional
images
FDR D-EVO GL utilizes the latest Fujifilm digital image processing
technology, including Dynamic
Visualization, which optimizes image display based on recognition of contrast levels throughout
the entire exposure field. The resulting first-up images have outstanding detail and greater window and
leveling capability in PACS.
Patented ISS capture technology promotes high sensitivity
Fujifilm's
proprietary Irradiated Side Sampling (ISS) positions its capture electronics (TFTs) at the irradiation
side, in contrast to traditional detectors. This design significantly suppresses scattering and
attenuation of X-ray signals, improving efficiency to produce sharper images at lower doses compared to
traditional designs.**
- High resolution images
- Increased sharpness
- High DQE
- Improved dose efficiency
SmartSwitch Technology
Fujifilm's SmartSwitch technology enables automatic
x-ray detection. FDR D-EVO GL automatically senses exposures to trigger image capture, allowing easier,
faster interfacing with any x-ray system.
*Excluding breast imaging. Virtual Grid requires FDX Console Version 9 or greater application
software.
** Based on higher MTF and DQE demonstrated in "Effect of X-ray incident direction and
scintillator layer design on image quality of indirect-conversion flat-panel detector with GOS
phosphor" by K. Sato, et al.